Features  DPI 104數字午夜小网站_德魯克午夜小网站

• 0.05% full scale (FS) accuracy

• Pressure ranges to 20,000 psi (1400 bar) 

• Eleven selectable pressure units

• Large, easy-to-read display with five-digit resolution

•% pressure indication and additional bar graph for quick visual reference

• Temperature compensated accuracy from 14°F to 122°F (-10°C to 50°C)

• 0 to 5V analog output

• Pressure switch test 

• Minimum/maximum, tare and alarm functions 

• IDOS compatible and RS232 serial interface 

• Free of charge monitoring and control software 

• Stainless steel or Inconel pressure cavity for aggressive media

Applications 

• Process monitoring and control 

• Test and calibration 

The DPI 104 is a microprocessor-controlled digital pressure gauge that combines precision and functionality in a compact, robust and simple-to-use package. 

The DPI 104 matches advanced silicon sensor technology with several convenient design features, resulting in an accurate, versatile yet affordable digital test gauge. 

Supplied as a stand-alone process indicator or in a kit with the widely proven Druck hand pumps, the DPI 104 provides a reliable and economic solution for a wide range of pressure sensing applications.

DRUCK表頭_DPI 104數字午夜小网站_德魯克午夜小网站

DPI 104 Specifications Accuracy 0.05% FS including non-linearity, hysteresis, repeatability and temperature effects from 14°F to 122°F (-10°C to 50°C) 

Resolution 

Maximum five digits

Burst Pressure Burst pressure is 2x working pressure (exception, 20,000 psi (1400 bar); burst pressure 29,000 psi (2000 bar). Selectable Pressure Units kPa, MPa, kg/cm2, psi, mbar, bar, inHg, inH2O, mH2O,mmH2O andmmHg Display 

• Pressure reading: 5 digits with 0.5 in (12.7mm character height 

• Full scale indicator: 2.5 digits with 0.25 in (6.35mm) character height Pressure Bar Graph In addition to the numeric pressure indication, the DPI 104 LCD display contains a circular twenty segment bar graph to provide the user with a quick visual estimation of pressure from 0 to 100% full scale output. The bar graph increments represent 5% of the userselectable range.

Display update 

Two times per second 

Minimum/Maximum Values The minimum and maximum pressure values can be displayed on the DPI 104. This function can be enabled/disabled, and reset by the user. 

Switch Test The DPI 104 features a switch test function that will capture and display the open and closed values from an external pressure switch. Maximum switch impedance 200 Ω. 

Voltage Output The DPI 104 can be programmed to provide a 0 to 5 V output signal that can be configured as directly proportional to the pressure shown in the display or set to a fixed value. The voltage output mode provides 0.1% FS accuracy from 50mV to 5 V. 

Alarm Output The alarm output consists of an open drain field effect transistor (maximum current 250mA, maximum voltage 24 VDC) Adjustable Mounting Positions For added convenience, the DPI 104 housing will rotate 320° around the pressure fitting and the faceplate can be rotated in any orientation for optimum visibility. 

Menu Lock To guard against unauthorized menu access, the DPI 104 features a menu and tare lock function RS232 Interface Serial communications are provided to allow transfer of data to a PC with the optional serial lead (IA4090-2-V0). 

Using this link, all menu commands and display data are available via an ASCII command set or the optional SiCal Pro Software. Network Capability Up to 99 DPI 104 instruments can be connected together in a daisy chain-configured network. 

Universal Pressure Module (UPM) Capability UPM modules can be connected to the DPI 104 to enhance the accuracy and extend the pressure range.

Battery The DPI 104 is supplied with a 9V alkaline battery, type MN1604. Battery life is approximay six months when used daily for one hour per day. For increased performance a 9V lithium battery (not supplied by GE) is suggested. Pressure Port

• 1/4 NPT or BSP male for units to 10,000 psi (700 bar) 

• 9/16x18 UNF male cone connection 15,000 psi (1000 bar) and 20,000 psi (1400 bar) units Enclosure 

• Case material: ABS/PC plastic sealed to Type 4/ IP65 

• Wetted parts: All stainless steel (316) or Inconel welded pressure cavity for compatibility with aggressive media. 

European Compliance CE marked SiCalPro Software This software package allows the user to control the DPI 104 remoy through a virtual instrument panel on the computer screen. 

The calibration data can be logged, viewed and printed in graphical format or as a calibration certificate. 

SiCalPro is free to download from the DPI 104 web page at http://www.ge-mcs. com/en/pressure-and-level/handheld-test-tools/ dpi-104-digital-test-gauge.html Option (B) PC serial lead required. Option (A) external power supply recommended. 

System Requirements Minimum In Pentium with Windows® 95 or higher General Storage Temperature -4°F to 158°F (-20°C to 70°C) Dimensions Diameter: 3.74 in (95mm) excluding pressure fittings Depth: 2.17 in (55mm) Weight 13 oz (350 g) approximate Mechanical Vibration To Def Stan 66-31, 8.4 Cat III Mechanical Shock To BS EN 61010:2001 Electrical Environments

• EMC: BS EN61326-1:1998+A2:2001

• Electrical Safety: BS EN 61010:2001 

• Mechanical Safety Pressure Equipment Directive—Class: Sound Engineering Practice (SEP) 

Options 

A) DPI 104 external power supply unit with lead p/n 191-350 

B) PC serial lead for connection to PC p/n IA4090-2-V0. (Note: Option A is recommended with PC serial lead.) 

E) Mating plug for eight-pin socket for switch test, voltage output, external power and alarm function (customers wishing to make their own connections/ leads) p/n 1S-04-0027 

F) 9/16x18 UNF to 3/8 BSP adapter for connection to PV 212 p/n 182-190 

G) DPI 104 UPM power lead for use with UPM IDOS Sensor p/n IA4101-1-V0. Requires Option H. 

H) Universal 12V external power supply for use with the UPM IDOS remote sensor p/n 191-129 Ordering Information Please state the following (where applicable) 1. Model DPI 104 2. Pressure range, type (G, A or SG) and pressure connections required. 3. 

Options, if required. Please order as separate items.

Pneumatic and Hydraulic Test Kits 

The DPI 104 is included as a standard component in these test and calibration kits: 

Low Pressure Pneumatic Test Kit Includes: DPI 104; ranges to 30 psi (2 bar), PV 210 low pressure pneumatic test pump, hose, adaptors, seal kit and case. 

Pneumatic Test Kit Includes: DPI 104; ranges to 300 psi (20 bar), PV 211 pneumatic test pump, hose, adaptors, seal kit and case.

Hydraulic Test Kit Includes: DPI 104; ranges to 15,000 psi (1000 bar), PV 212 hydraulic test pump, hose, adaptors, seal kit and case. 

Pneumatic and Hydraulic Test Kit Includes: DPI 104; ranges to 10,000 psi (700 bar), PV 411A combined pneumatic and hydraulic test pump, hydraulic reservoir, hose, adaptors, seal kit and case.

 

該產品由深圳市午夜性爱福利電子科技有限公司提供,銷售商地址位於深圳市南山區前海路振業國際商務中心1206。請您仔細閱讀產品使用說明書,正確使用。

如果想試用該產品,請以下單位:

 

午夜性爱福利電子主要銷售通信設備、儀器儀表、電力設備、熱工儀表、校準設備及工具配件。

關閉>>

掃一掃

歡迎關注午夜性爱福利網站平台

聯係午夜性爱福利

名稱:極儀午夜性爱福利

客服電話:0755-23964199,86564199

E-mail:service@1001718.com

傳真:0755-23964199

郵編:518052

Copyright © 2024-2025 深圳市午夜性爱福利電子科技有限公司 版權所有網站地圖 ICP備案號:粵ICP備15021421號
極儀午夜性爱福利 製作維護

0755-23964199
0775-86564199

微信掃一掃,給我發消息吧

 
網站地圖